光纜型號(hào)
光纜參考直徑
(mm)
光纜參考重量
(kg/km)
緊套光纖
直徑(µm)
允許拉伸力
長(zhǎng)期/短期
(N)
允許壓扁力
長(zhǎng)期/短期
(N/100mm)
彎曲半徑
動(dòng)態(tài)/靜態(tài)
(mm)
PVC護(hù)套
LSZH護(hù)套
GJFJ8V
(3.4±0.3)×(1.6±0.3)
4.8
5.3
600±50
40/80
100/500 60/30
GJFJ8V
(4.0±0.3)×(1.9±0.3)
8.0
8.7
900±50
100/200
100/500 60/30
GJFJ8V
(5.8±0.3)×(2.8±0.3)
11.6
14.8
900±50
100/200
100/500 60/30
-
光纖類(lèi)型
衰減
滿(mǎn)注入帶寬
有效模式帶寬
10G以太網(wǎng)鏈路長(zhǎng)度
最小彎曲半徑
條件
1310/1550nm
850/1300nm
850/1300nm
850nm
850nm
/
典型值
最大值
典型值
最大值
單位
dB/km
dB/km
dB/km
dB/km
MHZ.km
MHZ.km
m
mm
G652D
0.36/0.22
0.5/0.4
---
---
---
---
---
16
G657A1
0.36/0.22
0.5/0.4
---
---
---
---
---
10
G657A2
0.36/0.22
0.5/0.4
---
---
---
---
---
7.5
50/125
---
---
3.0/1.0
3.5/1.5
≥500/500
---
---
30
62.5/125
---
---
3.0/1.0
3.5/1.5
≥200/500
---
---
30
OM3
---
---
3.0/1.0
3.5/1.5
≥1500/500
≥2000
≤300
30
OM4
---
---
3.0/1.0
3.5/1.5
≥3500/500
≥4700
≤550
30
BI-OM3
---
---
3.0/1.0
3.5/1.5
≥1500/500
≥2000
≤300
7.5
BI-OM4
---
---
3.0/1.0
3.5/1.5
≥3500/500
≥4700
≤550
7.5
· 室內(nèi)光纜一般用于建筑物內(nèi)部通信
· 室內(nèi)光纜大多采用緊套光纖或單芯纜為基本單
· 由于室內(nèi)光纜所具有的細(xì)小、柔軟、 阻燃、
接方便等特點(diǎn),因此,非常適合室內(nèi)壞
境下的通信選擇,常用作通訊設(shè)備的
尾纖或布線(xiàn)。